    Procedure for Handling Explosion proof Certificate of GB/T3836 Standard

    SINO Testing Services

    | 2020-06-22|Return

    In places where explosive mixtures are commonly present in industries such as coal, petroleum, chemical, textile, and grain processing, such as production, processing, storage, and transportation, if an explosion occurs, the harm is extremely great. Therefore, the equipment used and installed in such places generally requires the product to adopt suitable explosion-proof protection types and measures, pass relevant national explosion-proof standard tests, and obtain corresponding explosion-proof certificates to avoid causing explosions in the surrounding environment.

    Explosion proof certificate: It is a document used to determine whether the equipment meets the requirements of explosion-proof standards, type tests, and routine tests for adaptation. The certificate can be for Ex devices or Ex components.

    So, what are the requirements for applying for an explosion-proof certificate for equipment?
    STS briefly introduced the procedure below.

    ◆ Data preparation requirements

    (1) Applicant's Business License

    (2) Product enterprise standards. Enterprise standards should include the name of the enterprise standard, the enterprise number, the date of publication and implementation, the basis for writing, the proposer, the drafter, the referenced documents, product specifications and models, basic parameters, explosion-proof markings, environmental conditions for use, explosion-proof related technical conditions, testing methods, inspection rules, judgment methods, product markings, packaging and transportation conditions, etc.

    (3) Product user manual. The instruction manual should include the basic parameters of the product, environmental conditions for use, explosion-proof signs, product appearance, installation and use specifications, safety precautions, warning language, and other precautions related to explosion-proof.

    (4) Product drawings. The drawings should include general assembly drawings, explosion-proof related component drawings, circuit schematics, printed circuit board drawings, screen printing drawings, component material lists, nameplate drawings, etc. Drawings unrelated to explosion-proof may not be provided. The explosion-proof structure and parameters should be reflected in the drawings.

    (5) Model specification description, if it is a series product, there should also be a model specification description.

    (6) Process documents. For example, for products with pouring and sealing structures, pouring and sealing process documents need to be provided.

    (7) Battery specification sheet. For example, products containing batteries need to be provided.

    (8) If components that have obtained explosion-proof certification are used in the product, the corresponding explosion-proof certification of the components must be provided.

    ◆ Sample preparation requirements

    According to the product specifications, model series, representative products should be submitted for inspection, and the samples submitted for inspection should be consistent with the provided product drawings. The number of prototypes depends on the explosion-proof type and specifications of the product, usually 1-3 pieces. Three pieces of glass are required for glass components, three samples are required for n-type or sealed types, and at least one set of components before sealing is required for sealed types. Non metallic standard samples are required for components with non-metallic shells; If there are special dismantling structures, dismantling tools and other materials required for testing should be provided.

    ◆ Detection stage

    The main work during the testing phase is in the testing laboratory. However, if the product testing fails and needs to be rectified, the enterprise needs to actively cooperate with the rectification to meet the requirements of explosion-proof standards.

    ◆ Certificate acquisition stage

    (1) Upon receiving the certificate and report, the first step is to check for any errors in the information.

    (2) Go online to check if the certificate number matches the paper certificate, and confirm the authenticity of the certificate.

    圖片2.png




    Related Recommendations
    Contact us
    0755-2102 2109
    Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
    Follow us
    Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
    Service Hotline
    18924609560
    點擊這里給我發(fā)消息 1354407946
    點擊這里給我發(fā)消息 1354407946
    欧美国产日韩在线播放_欧亚日韩在线_欧洲成人午夜精品无码区久久_在线免费亚洲无码视频_国产成人精品区在线观看_亚洲av麻豆天堂_亚洲所有免费观看视频_国产av永久网_亚洲国产一区日韩欧美_亚洲AV日韩AV天堂影片精品一 网站地图
    亚洲无码激情视频在线观看 | 久国产精品久久精品国产四虎 | 亚洲av乱码国产精品观看麻豆 | 国产精品视频公开费视频 | 亚洲无码精彩视频在线观看 | 亚洲一区二区综合色精品 | 欧美亚洲日本国产综合网 | 欧美精品一区视频 | 久久丝袜国产精品 | 国产精品欧美在线观看 | 一区二区日韩国产精品 | 亚洲福利中文av在线 | 首页日韩欧美国产精品 | 亚洲欧美成人A∨在线观看 亚洲aⅴ无码日韩av无码网站 | 亚洲a码在线观看 | 久久精品国产亚洲av高清乱 | 国产成人一区二区在线 | 国产丝袜无码一区二区视频 | 国产精品亚洲一区在现观看 | 国产视频亚洲专区在线观看 | 亚洲AV午夜精品一区二区三区 | 久久亚洲高清国产 | 国产国语对白三级在线观看中文 | 亚洲日韩中文字幕久热 | 久久免费区一区二区三波多野 | 亚洲国产精品乱码一区二区三区 | 日韩精品无码免费视频三区 | 国产成人无码一二三区视频 | 国产精品免费网站 | 天堂亚洲欧美日韩一区二区 | 亚洲综合视频一区二区 | 久久中文亚洲国产 | 中文字幕无码专区dvd在线 | 亚洲av成人一区国产精品动漫 | 无码国产精品午夜福利 | 成人国产综合一区二区在线观看 | 亚州精品无码人妻久久 | 亚洲一区av免费在线观看 | 亚洲va欧美va国产va在线 | 日韩精品一区二区三区熟女 | 亚洲欧美国产高清va在线播放 |