    Interpretation of ATEX EU's latest explosion-proof certification directive 2014/34/EU and related issues

    SINO Testing Services

    | 2019-12-12|Return

    With the rapid development of China's economic construction and the increasing scale of industrial production, the issue of explosion prevention has become more important. Explosion proof electrical products with diverse functions and varieties are widely used in various industries such as petroleum, chemical, and coal. Whether explosion-proof electrical appliances can operate stably and safely in various hazardous explosive environments during use requires strict explosion-proof testing before leaving the factory. Shenzhen Zhongnuo Testing Technology Co., Ltd. has rich experience in product design and testing in the field of explosion-proof. The following is an interpretation of the latest EU explosion-proof ATEX certification directive 2014/34/EU and related issues.

     

    Explosion proof Directive ATEX 2014/34/EU
    (Old Directive 94/9/EC)

    ATEX originated from the French word "ATmosphere EXlosible". On March 23, 1994, the European Commission adopted the Directive "Equipment and Protective Systems for Potential Explosive Environments" (94/9/EC). This directive has been in use since 1996 and was enforced on July 1, 2003.


    This directive covers both mining and non mining equipment. Unlike previous directives, it includes mechanical and electrical equipment, extending the potential explosive hazard environment to dust and flammable gases, flammable vapors, and mist in the air. This directive is commonly referred to as the ATEX 100A "New Method" directive, which is the current ATEX Explosion Protection Directive.


    Manufacturers of equipment intended for use in potentially explosive environments can sell their explosion-proof equipment anywhere in Europe without considering additional requirements, by applying the ATEX directive provisions and affixing the CE mark.

    There are three prerequisites for applying this instruction:

    1. The device must have its own ignition source;

    2. Expected to be used in potentially explosive environments (air mixtures);

    3. Under normal atmospheric conditions.

    This instruction also applies to components necessary for safe use, as well as safety devices that directly benefit the safe use of equipment within the scope of application. These devices can be installed outside of potentially explosive environments.

    ATEX2014/34/EUThe instruction divides the equipment into three categories based on the protection level of the installed equipment:

    Category 1- Very high level of protection

    Category 2- High level of protection

    Category 3- Normal level of protection

    If the device is used in zone 0, 1, or 2, the category number is followed by the letter G (gas, vapor/mist):

    Zone 0, Zone 1, Zone 2

    1G devices, 2G devices, 3G devices

    If the device is used in zones 20, 21, or 22, the category number is followed by the letter D (dust):

    Zone 20, Zone 21, Zone 22

    1D devices, 2D devices, 3D devices

    Zone 0: zone 0, Places where explosive gas environments occur continuously or exist for a long time, and the duration of hazardous environments is greater than 1000 hours per year.

    Zone 1: zone 1, In places where explosive gas environments may occur during normal operation, the duration of hazardous environments is between 10-1000 hours per year.

    Zone 2: zone 2, During normal operation, it is impossible to have an explosive gas environment. If it does occur occasionally and only for a short period of time, the hazardous environment will exist for less than 10 hours per year

    (2) ATEX Directive 1999/92/EC

    ATEX 1999/92/EC and ATEX2014/34/EUDirective Parallel is a minimum requirement for improving the health and safety protection of workers in potentially explosive hazardous environments (1999/92/EC), also known as ATEX 137, which specifies the minimum requirements for improving the health and safety protection of workers in potentially explosive hazardous environments.

    This means that based on the assessment of the risks involved, employers bear a significant amount of responsibility:

    1. Prevent the formation of explosive environments in the workplace or avoid igniting explosive environments;

    2. Conduct a hazard assessment of explosive environments and ignition sources;

    3. Divide the workplace according to the frequency and time of explosive environments;

    4. Mark the area with symbols (Ex symbol) at the entrance;

    5. Establish and maintain an explosion-proof document;

    6. Select ATEX compliant hazardous areas based on the intended use2014/34/EUThe equipment required by the instruction.

    ATEX 1999/92/EC regulations:

    Only Class 1 equipment can be used in Zone 0 locations; Only Class 1 and Class 2 equipment can be used in Zone 1 locations; Only Class 1, 2, and 3 equipment can be used in Zone 2 locations.

    This directive specifies the responsibilities of employers rather than manufacturers.

    ATEX防爆標(biāo)志-氣體環(huán)境.jpg

    New Explosion Protection Directive 2014/34/EU Explanation
    The new version of the Explosion Protection Directive 2014/34/EU was published in the EU Official Journal on March 29, 2014 and came into effect on April 18, 2014. The new explosion-proof directive 2014/34/EU will be officially implemented on April 20, 2016, and the old directive 94/9/EC will also be replaced accordingly. With the update of the directive, the European Commission will implement the explosion-proof directive regulations based on the new legislative framework (NLF).


    The new version of the directive introduces a new legislative framework (NLF) that provides more detailed provisions on the obligations of distributors, while maintaining the same product scope, product classification, basic safety requirements, and consistency assessment process. At the same time, under the new NFL architecture, the requirements for announcement agencies in the certification process are more refined, and the responsibilities of agencies in the certification process are more clearly defined.

    What are the changes in the new instructions
    Q:Has there been any change in the product scope of the new explosion-proof directive 2014/34/EU?

    A:The overall situation remains unchanged. Compared to the old instructions, the only difference is the wording, but the content remains consistent.

      

    Q:When will the new version of the explosion-proof directive be used?

    A:The new version of the directive was released on March 29, 2014; Effective on April 18, 2014; Implemented on April 20th, 2016.

      

    Q:When can the certificate for the new explosion-proof directive 2014/34/EU be issued?

    A:The new version of the directive certificate can only be issued from April 20, 2016. Prior to this date, the notified body can only make relevant preparations and is not allowed to issue certificates for the new version of the directive. Prior to this date, the notified body could only issue certificates for the old version of the Explosion Protection Directive 94/9/EC.

    Q:When the new version of the Explosion Protection Directive 2014/34/EU is officially implemented, are the certificates of the old version of the directive valid?

    A:Still effective. As long as the certificate of the old version of the explosion-proof directive 94/9/EC is still valid, the certificate will remain valid.

      

    Q:What should I pay attention to when using the old version of the explosion-proof directive 94/9/EC certificate after April 20, 2016?

    A:Customers holding certificates of the old version of the directive need to pay attention to providing a declaration of conformity for the new version of the explosion-proof directive 2014/34/EU when providing a declaration of conformity.

      

    Q:After April 20, 2016, can certificates issued according to the old version of the directive be reviewed annually or updated for renewal?
    A:sure. The annual review or renewal of certificates will be carried out in accordance with the new instructions.

      

    Q:Can the manufacturer sign and provide a declaration of conformity based on the new version of the directive on April 20, 2016?

    A:no way. The compliance declaration related to the new version of the directive can only be signed from April 20, 2016 onwards


    Service Hotline: 18924609560 (same WeChat account)



    Related Recommendations
    Contact us
    0755-2102 2109
    Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
    Follow us
    Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號(hào)
    Service Hotline
    18924609560
    點(diǎn)擊這里給我發(fā)消息 1354407946
    點(diǎn)擊這里給我發(fā)消息 1354407946
    欧美国产日韩在线播放_欧亚日韩在线_欧洲成人午夜精品无码区久久_在线免费亚洲无码视频_国产成人精品区在线观看_亚洲av麻豆天堂_亚洲所有免费观看视频_国产av永久网_亚洲国产一区日韩欧美_亚洲AV日韩AV天堂影片精品一 网站地图
    国产一级农村无码 | 国产午夜福利亚洲第一 | 麻豆aⅴ精品无码一区二区 一区二区日韩国产精品 | 狼人精品一区二区三区在线 | 亚洲欧美国产专区 | 亚洲精品中文av字幕乱码在线观看 | av中文字幕精品在线 | 国产无码第十页 | 亚洲精品中文字幕麻豆 | 麻豆aⅴ精品无码一区二区 一区二区日韩国产精品 | 在线视频这里只有精品 | 亚洲人成网亚洲欧洲无码 | 日韩精品无码免费视频三区 | 首页中文字幕在线视频 | 欧美激情国产精品免费 | 亚洲AV无码一区二区三区四区 | 国产不卡av电影在线 | 精品无码三级在线观看视频 | 欧美国产日韩亚洲综合 | 在线观看视频一区 | 亚洲自拍一区视频 | 欧美日韩国产一区二区三区地区 | 国产精品欧美在线观看 | 亚洲综合视频一区二区 | 中文字幕永久网址 | 欧美一区啪啪视频 | 国内大量揄拍人妻精品視頻 | 国产精品福利在线一区二区 | 日韩AV无码一区二区三 | 日韩一区二区三区无码人妻视频 | 国产精品欧美在线观看 | 一区二区精品视频国产 | 精品一区二区制服诱惑免费 | 有码精品一二区在线 | 国产人成无码视频在线 | 国产亚洲欧美在线一区二区 | 亚洲成人av一区二区在线观看 | 国产精品熟女丝袜一区二区三区 | 国产成人亚洲综合无码精品 | 亚洲综合AV一区二区三区不卡 | 久国产精品久久精品国产四虎 |